High-rise fire safety: what residents need to know in 2026

Since the Grenfell Tower fire in 2017, the UK has passed the Fire Safety Act 2021, the Building Safety Act 2022, and a series of regulations that changed inspection requirements, resident rights, and evacuation strategies for high-rise residential buildings. This guide explains what has changed and what it means for you.

Based on Building Safety Act 2022, Fire Safety (England) Regulations 2022, and Grenfell Tower Inquiry findings.

Regulatory timeline

Key changes since Grenfell (2018–2023)

2018 Sprinklers required in new build residential tower blocks over 11 m (England)
2019 Ban on combustible materials in external walls of buildings over 18 m (extended to 11 m in 2022)
2020 Fire Safety Act consultations; EWS1 form introduced for mortgage assessments
2021 Fire Safety Act 2021 passed — clarifies RRO scope includes external walls and flat entrance doors
2022 Building Safety Act 2022: BSR created; Fire Safety (England) Regulations 2022 — quarterly fire door checks
2023 Leaseholder protections strengthened; developer pledge on remediation costs; BSR begins registration

Stay put vs simultaneous evacuation

The traditional "stay put" strategy relies on compartmentation — fire-resistant walls, floors, and fire doors that contain a fire to the flat of origin while occupants in adjacent flats remain safely in place. This strategy is still valid in buildings where compartmentation is intact and confirmed. However, buildings with ACM cladding, combustible render, or inadequate fire doors may be on a simultaneous evacuation strategy — meaning all residents should leave on the alarm. If you do not know which strategy applies to your building, contact your building management company. This information must be displayed in common areas under the Fire Safety (England) Regulations 2022.

If you are ever unsure — evacuate

If there is any doubt about what strategy applies, or if you can smell smoke, see fire, or your flat becomes smoke-filled, evacuate via the stairs immediately. Close all doors as you leave. Never use the lift. Go to your designated assembly point and do not re-enter.

Fire door checks: what residents can do

Residents can carry out basic checks on their flat entrance door without specialist training. Use the six-point check in our fire door safety guide: confirm the self-closer works, check for gaps greater than 3 mm, look for intact intumescent seals, and check no modifications have been made that would compromise the rating. Report any defect to the building manager in writing. Under the Fire Safety (England) Regulations 2022, flat entrance door inspections are the responsibility of the responsible person — but residents play a critical role in identifying day-to-day defects.

The Building Safety Act 2022: resident rights

The Building Safety Act created a new framework of rights and protections for residents in higher-risk buildings (18 m+). Key points: accountable persons must maintain a resident engagement strategy; residents have the right to request safety information; safety cases must be registered with the BSR; and developers — not leaseholders — are expected to fund remediation of historical cladding defects in most cases. The Act also introduced protections against retaliatory eviction for residents who raise legitimate safety concerns. For a full overview of tenant rights, see our fire safety for renters guide and our Fire Safety Act 2022 explainer.

High-rise fire safety FAQ

Questions about high-rise fire safety